Related Products
Description
Main power supply 230V~/240V~, +/-10%, 50/60 Hz
Valve power supply (24V~/= or 230V~/240V~): 4A Max for all valves
Consumption: 2 to 15 VA depending on the number of elements connected to the bus and the number and type of controlled valve actuator
8 outputs powered working contact for controlling the valves
Permanent current: 1A Max per output, 230V~/240V~ +/-10%
Accepted inrush current: 2A max. per channel, 6A max. for all channels
2 dry contact outputs controlling the burner and circulator (2A Max per output,
230V~/240V~ +/-10%)
1 change-over input or output (according to SW6 configuration)
2 communication buses for connecting the thermostats (star cabling)
1.C action (brownout)
Class II insulation
Surface-mounted
Dimensions: 250 x 95 x 43 mm
Degree of protection: IP 33
Operating temperature: 0°C to +50°C
Storage temperature: -10°C to +70°C
Installation in an environment with normal pollution levels
Anti-seize function (automatic start-up 1 to 10 minutes/week if the event that the valve and circulator remain idle
5 Year Warranty